Installation architecture
Parts are divided into four zones. Identifying the zone concerned is the first diagnostic reflex: it immediately narrows down the possible references.
Sensor on the car roof
The sensor reads the magnetic strip as it passes and calculates the absolute position. Its LEDs allow immediate on-site diagnosis.
Related parts: Solimax · sensor · rangefinder
Magnetic strip in the shaft
Stainless steel strip coded on 15 bits, stretched over the whole travel. A spring and a safety contact monitor its tension and detect a break.
Related parts: magnetic strip · Limax
Safety box
It carries the SIL3-certified safety functions and communicates with the controller via CANopen bus.
Related parts: Solimax box · board
Link with the controller
The CANopen bus transmits position and safety states. On QI Touch installations, the Solimax learning is one of the commissioning steps.
Related parts: QI Touch · board · wiring
Points of attention
- SoLIMAX is a SIL3-certified safety component: replacing it is a supervised intervention, with tests before return to service.
- The length of magnetic strip depends on the travel: 100 m in Quick Install configuration, 268 m maximum. Measure the actual travel before ordering.
- Safety values are adjustable within defined ranges — anti-drift zone from 20 to 350 mm, levelling from 20 to 140 mm, travel limits from 30 to 100 mm. Any setting outside the range is refused by the device.
- The maximum permitted speed is 3 m/s in Quick Install and 10 m/s in full configuration: check your unit’s rated speed.
- The strip tension monitoring contact is part of the safety chain: a slack or broken strip stops the unit.
- On a QI Touch installation, the Solimax learning is a separate commissioning step, to be redone after replacement.
Get a quote
State the part reference if you know it, the number of levels and accesses of the unit, the type of wiring and your wilaya. A photo of the part in place and its markings confirms the match. KMY confirms the final price, availability and delivery time in Algeria.
Search all SoLIMAX parts in the catalogue ↗
Source of the specifications: SODIMAS SoLIMAX data sheet ref. 27SO053P00007FR and EU declaration of conformity ref. 25-04-H067 (29/04/2025). Data reproduced for information only; only the manufacturer’s documentation is authoritative. Specifications may change between versions.